Published on: October 2026
ASSESSMENT OF WATER POLLUTION IN THE KHARUN RIVER AND EVALUATION OF A 50 MLD SBR-BASED SEWAGE TREATMENT PLANT AS A FUTURE INTERVENTION FOR POLLUTION MITIGATION IN RAIPUR, CHHATTISGARH
Koushal Choudhary
Dr. Rakhi Soni
Raipur Institute of Technology, Raipur,
India
Article Status
Available Documents
Abstract
In addition to river-water assessment, a 50 million litres per day (MLD) Sequencing Batch Reactor (SBR)-based STP is proposed for treatment of domestic sewage entering the river system. The preliminary design considers an average sewage flow of 50,000 m³/day and a peak flow of 100,000 m³/day. Based on an assumed raw sewage BOD concentration of 250 mg/L, the estimated BOD load is 12,500 kg/day. Approximately 28,000 m³ of total SBR working volume is proposed, divided into five parallel basins.
Keywords - Kharun River; Water Quality Index; WQI; sewage treatment; Sequencing Batch Reactor; SBR; BOD.
How to Cite this Paper
Choudhary, K. (2026). Assessment of Water Pollution in the Kharun River and Evaluation of a 50 MLD SBR-Based Sewage Treatment Plant as a Future intervention for Pollution Mitigation in Raipur, Chhattisgarh. International Journal of Creative and Open Research in Engineering and Management, <i>02</i>(10), 1-9. https://doi.org/10.55041/ijcope.v2i10.035
Choudhary, Koushal. "Assessment of Water Pollution in the Kharun River and Evaluation of a 50 MLD SBR-Based Sewage Treatment Plant as a Future intervention for Pollution Mitigation in Raipur, Chhattisgarh." International Journal of Creative and Open Research in Engineering and Management, vol. 02, no. 10, 2026, pp. 1-9. doi:https://doi.org/10.55041/ijcope.v2i10.035.
Choudhary, Koushal. "Assessment of Water Pollution in the Kharun River and Evaluation of a 50 MLD SBR-Based Sewage Treatment Plant as a Future intervention for Pollution Mitigation in Raipur, Chhattisgarh." International Journal of Creative and Open Research in Engineering and Management 02, no. 10 (2026): 1-9. https://doi.org/https://doi.org/10.55041/ijcope.v2i10.035.
References
- Horton RK. An index-number system for rating water quality. J Water Pollut Control Fed. 1965;37(3):300-306.
- Brown RM, McClelland NI, Deininger RA, Tozer RG. A water quality index—do we dare? Water Sew Works. 1970;117(10):339-343.
- Tyagi S, Sharma B, Singh P, Dobhal R. Water quality assessment in terms of water quality index. Am J Water Resour. 2013;1(3):34-38. doi:10.12691/ajwr-1-3-3.
- Goyal S, Shrivastava S. Physico-chemical analysis of Kharun River water in Raipur, CG, India. Int Res J Environ Sci. 2020;9(3):72-74.
- Shivhare A, Upadhyay A, Sinha P. Study of physio-chemical parameter of Kharun River and concentration of heavy metal (Iron). J Ravishankar Univ B Sci. 2025;38(2). doi:10.52228/JRUB.2025-38-2-6.
- Singh M, Srivastava RK. Sequencing batch reactor technology for biological wastewater treatment: a review. Asia-Pac J Chem Eng. 2011;6(1):3-13. doi:10.1002/apj.490.
Ethical Compliance & Review Process
- •All submissions are screened under plagiarism detection.
- •Review follows editorial policy.
- •Authors retain copyright.
- •Peer Review Type: Double-Blind Peer Review
- •Published on: Oct 07 2026
This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. You are free to share and adapt this work for non-commercial purposes with proper attribution.